title: Appendix
slug: ag-25x/appendix
createdAt: 2026-07-27T04:11:10.716Z
---

### SPAN

Switched Port Analyzer (SPAN) allows you to send a copy of traffic passing through ports to another port on the switch. SPAN is important to mirror received or transmitted (or both) traffic on one or more source ports to a destination port for analysis.

SPAN is mirroring ports in the same switch, RSPAN (Remote SPAN) is mirroring ports in one switch to a port in different switch.

This example describes how to configure RSPAN on Cisco Catalyst switches (Cisco 2960).

### RSPAN

A sample topology to monitor traffic on port Gi0/1 in Switch1 using a IPS Profiler connected to port Gi0/2 in Switch2 is shown below.

Create a VLAN that will be used as an RSPAN-VLAN on both switches. In this example vlan ID 999 is used as the RSPAN-VLAN. Allow the RSPAN-VLAN on the trunk port between Switch1 and Switch2.

::Image[]{src="https://api.archbee.com/api/optimize/wxZG1KsS4xNkVZYoiu_o9/BowwE7ZGb0MBOOEGxGuxF_rspan.png" position="flex-start" size="39" width="389" height="256" initialPath="images/rspan.png" githubPath="images/rspan.png" darkWidth="389" darkHeight="256" showCaption="false"}

**Switch1 (Source switch**)

```bash
Switch1#conf t
Enter configuration commands, one per line.  End with CNTL/Z.
Switch1(config)#vlan 999
Switch1(config-vlan)#name RSPAN-Vlan
Switch1(config-vlan)#remote-span
Switch1(config-vlan)#exit
Switch1(config)#monitor session 1 source interface Gi0/1
Switch1(config)#monitor session 1 destination remote vlan 999
Switch1(config)#end
```

<font color="#000000">**Allow VLAN ID 999 on the trunk port Gi0/2**</font>

```bash
Switch1#sh run int g0/2
Building configuration...
Current configuration : 175 bytes
!
interface GigabitEthernet0/2
description To-Switch2-port-Gi0/1
switchport trunk allowed vlan 74,999
switchport mode trunk
end
```

<font color="#000000">**Switch2 (destination switch)**</font>

```bash
Switch2#conf t
Enter configuration commands, one per line.  End with CNTL/Z.
Switch2(config)#vlan 999
Switch2(config-vlan)#name RSPAN-Vlan
Switch2(config-vlan)#remote-span
Switch2(config-vlan)#exit
Switch2(config)#monitor session 1 source remote vlan 999
Switch2(config)#end
```

<font color="#000000">**Allow vlan id 999 on the trunk port Gi0/1**</font>

```bash
Switch2#sh run int g0/1
Building configuration...
Current configuration : 175 bytes
!
interface GigabitEthernet0/1
description To-Switch1-port-Gi0/2
switchport trunk allowed vlan 10,20,30,999,60
switchport mode trunk
end
Allow VLAN id 999 on trunk port Gi0/2.
Switch1#sh run int g0/2
Building configuration...
Current configuration : 175 bytes
!
interface GigabitEthernet0/2
description To-Switch2-port-Gi0/2
switchport trunk allowed vlan 60,999
switchport mode trunk
end
```

<font color="#000000">**NetFlow** </font>

NetFlow is a network protocol developed by Cisco for collecting IP traffic information and monitoring network traffic. Using a NetFlow collector and analyzer, you can see where network traffic is coming from and going to and how much traffic is being generated.

NetFlow V5 or V9 has to be configured on Cisco switch.

### Commands on Cisco Switch

```bash
ueba-switch(config)#flow exporter UEBA
ueba-switch(config-flow-exporter)# destination <IPS IP>
ueba-switch(config-flow-exporter)#transport udp 2055
ueba-switch(config-flow-exporter)#export-protocol netflow-v9 (or netflow-v5)
```

:::hint{type="info"}
Cisco 3850 Catalyst switches support only v9 whereas Cisco 2960 supports both v5 and v9
:::

```bash
ueba-switch(config)#flow record UEBA
  ueba-switch(config-flow-record)# match ipv4 protocol
  ueba-switch(config-flow-record)#match ipv4 source address
  ueba-switch(config-flow-record)#match ipv4 destination address
  ueba-switch(config-flow-record)# match transport source-port
  ueba-switch(config-flow-record)#match transport destination-port
  ueba-switch(config-flow-record)#match interface input
  ueba-switch(config-flow-record)#collect interface output
 ueba-switch(config)#flow monitor UEBA
  ueba-switch(config-flow-monitor)#exporter UEBA
  ueba-switch(config-flow-monitor)#cache timeout active 60
  ueba-switch(config-flow-monitor)#record UEBA
  ueba-switch(config)#interface GigabitEthernet1/0/3    ---(interface to which client endpoint is connected)
  ueba-switch(config-if)#ip flow monitor UEBA input
```